Image may not be representative of actual product.
Input voltage: 24 V DC (18 - 30 V DC)
Input current: 2 x 20 A
Total current: max. 40 A
Invers-polarity protection: max. 30 V DC
Auto-Balancing (50/50): no
Standards: EN 61000-6-2, EN 61000-6-3
Bridging concept: two sides, with spring clamp terminals or bridge set (max. 40 A)
Relative humidity: 5 - 95%, no condensation
Efficiency: 99.5%
Connection: Spring clamp terminals
Mounting method: DIN-rail mountable TH35 (EN 60715)
Temperature range: -25 - 60 degrees Celsius (storage temperature -40 - 85 degrees Celsius)
Output voltage: 24 V DC (18 - 30 V DC)
Output current: 40 A (-25 - 60 degrees Celsius); 52 A (-25 - 40 degrees Celsius); 26 A (-25 - 40 degrees Celsius)
LED display: LED (red/green)
Alarm output: potential free (relay contact) for input voltage
Murrelektronik offers a wide range of buffer modules that bridge voltage fluctuations for 38 seconds at 10 A or up to several minutes at 1 A. They are equipped with ultra capacitors instead of lead batteries like conventional uninterruptible power systems (UPS). This makes sure they are maintenance-free and cost-effective because you never have to change the batteries in Murrelektronik's buffer modules.
Murrelektronik Buffer/Redundancy Module Advantages:
Stable power supply
Safe processes
Increased machine availability
Input current: 2 x 20 A
Total current: max. 40 A
Invers-polarity protection: max. 30 V DC
Auto-Balancing (50/50): no
Standards: EN 61000-6-2, EN 61000-6-3
Bridging concept: two sides, with spring clamp terminals or bridge set (max. 40 A)
Relative humidity: 5 - 95%, no condensation
Efficiency: 99.5%
Connection: Spring clamp terminals
Mounting method: DIN-rail mountable TH35 (EN 60715)
Temperature range: -25 - 60 degrees Celsius (storage temperature -40 - 85 degrees Celsius)
Output voltage: 24 V DC (18 - 30 V DC)
Output current: 40 A (-25 - 60 degrees Celsius); 52 A (-25 - 40 degrees Celsius); 26 A (-25 - 40 degrees Celsius)
LED display: LED (red/green)
Alarm output: potential free (relay contact) for input voltage
Murrelektronik offers a wide range of buffer modules that bridge voltage fluctuations for 38 seconds at 10 A or up to several minutes at 1 A. They are equipped with ultra capacitors instead of lead batteries like conventional uninterruptible power systems (UPS). This makes sure they are maintenance-free and cost-effective because you never have to change the batteries in Murrelektronik's buffer modules.
Murrelektronik Buffer/Redundancy Module Advantages:
Stable power supply
Safe processes
Increased machine availability
Additional Info
Brand | Murrelektronik |
---|---|
Component Type | Redundancy Module |
Murr Product Series | Murrelektronik MB |