Image may not be representative of actual product.
Series: 112
Principle of physics: Ultrasonics
Application: Double sheet monitoring
Switching frequency: 200 Hz
Supply voltage: 18 - 30 V, DC
Number of teach inputs: 1
Number of digital switching outputs: 2
Switching output: 1
Switching element: Transistor, PNP
Function: Single sheet detected or >/= 1 sheet
Switching output: 2
Switching element: Transistor, PNP
Function: Double sheet detected or >/= 2 sheets
Connection: 1
Type of connection: Connector
Thread size: M12
Design: Cubic
Dimension (W x H x L) 84 mm x 37 mm x 98 mm
Operational controls: Teach button
Degree of protection: IP 65
Certifications: c UL US
Particularly in constrained spaces, such as in post-press processing, an M12 ultrasonic sensor reliably detects multi-layer paper and plastic sheets as well as metal foils.
Double sheet detection of paper, plastic and metal foils
Measurement range 20 g/m^2 to 800 g/m^2 (homogeneous cardboard)
Ultrasonic sensors in M12 cylindrical sensor housing, 20 mm housing length
Very small sensor construction
Indicator diodes for alignment and diagnostics
Teach button
Additional Info
Application Function | Double Sheet Monitoring, Teach Input |
---|---|
Brand | Leuze |
Component Type | Double Sheet Monitoring Sensor |
Connection | M12 Plug |
Leuze Product Series | Leuze DB 112B Double Sheet Monitoring Amplifier |
Output Type | PNP |