Image may not be representative of actual product.
Compatible with the following transmitter:
MLC500T20-2550 | 68000225
In order to install this light curtain you will also need to purchase a safety relay, 2 connector cables, and two mounting bracket sets: safety relay, connection cables, and mounting brackets.
Application: Finger protection
Characteristic Parameter Type: 4,IEC/EN 61496
Resolution: 20 mm
Protective field height: 2550 mm
Response time:44 ms
Supply voltage: 24 V, DC, -20-20 %
Number of safety-related switching outputs (OSSDs): 2 Piece(s)
Safety-related switching output 1: Switching element Transistor, PNP
Safety-related switching output 2: Switching element Transistor, PNP
Type of connection: Connector
Thread size: M12
No. of pins: 8 -pin
Housing material: Metal, Aluminum
Lens cover material: Plastic (PMMA)
Degree of protection: IP 65
Function package: Transmission channel changeover, Start/restart interlock (RES), Contactor monitoring (EDM), Fixed blanking without tolerance, Fixed blanking without tolerance, can be activated/deactivated during operation, Fixed blanking with 1-beam tolerance, Integration of contact-based safety circuit Integration of electronic safety-related switching outputs MaxiScan, Floating blanking, can be changed to fixed blanking during operation, Reduced resolution, can be changed to fixed blanking during operation, Combination of floating/fixed blanking, can be changed to fixed blanking during operation, Timing controlled 2-sensor muting, Muting-timeout extension, Partial muting
Whenever you need additional control functions, the MLC 530 Extended version is the perfect choice. With its 5 different operating modes, the integrated muting function and 3 different scan modes, the sensor leaves almost nothing to be desired. Device linking enables the construction of 2-channel, contact-based safety circuits as well as serial connections of several devices with safety-related switching outputs (OSSD).
Advantages:
Integrated function for timing controlled muting for temporary proper bridging of the protective function, e.g. when transporting materials through the protective field
Fixed or floating beam blanking, reduced resolution: necessary whenever objects must be in the protective field for operational reasons
Different scan modes: to adjust availability, select SingleScan, DoubleScan or MaxiScan
Teaching without PC: configuration and teaching, e.g. of floating beam blanking, is quick and easy
Additional Info
Brand | Leuze |
---|---|
Component Type | Receiver |
Field Height | 2550mm |
Leuze mlc 500 | Type 4 Safety Light Curtains |
Leuze Product Series | Leuze MLC 530 Receiver Extended Model with Blanking/Muting |
Resolution | 20mm - Hand Protection |
Safety Level | Type 4 |