Image may not be representative of actual product.
Shop for the Murrelektronik 56424 I/O system -
Type: for 3-wire sensors or mechanical switches, PNP
Sensor supply US: max. 200 mA from AS-Interface (short-circuit and overload protected)
Fieldbus: A-coded
I/O ports: M12, 4-pole
Bus voltage (AS-Interface): 26.5 - 31.6 V DC
ASI-Power 24: yes
Total current: max. 250 mA
Addressing: via master or M12 connection and programming device
Address range: 1 - 62 (2 x 1 - 31 A or B)
Profile (IO/ID/ID2 code): 2 x S-0.A.2
Address presetting: Slave 1: address 31 A; Slave 2: address 31 B
Protection: IP68
Mounting method: screw fixing
Temperature range: -20 - 60 degrees Celcius (storage temperature -20 - 70 degrees Celcius)
Dimensions H x W x D: 126x30x34.5 mm
Communication status: via LED
Diagnostic via LED: per module
Monitoring - no voltage: yes
The I/O modules of the Murrelektronik MASI68 series, with bus connections and M12 standard cables, are designed for applications in exposed areas that require sealed components. They offer a complete solution with IP68/69K protection. Accessories and special round cables complete the MASI68 range offering you a total installation concept for decentralized installations. Pluggable round cables make installation and service much easier.
Advantages:
Small and compact with high signal density
Sealed to meet industrial requirements
Easy to install with integrated bus distributor
Type: for 3-wire sensors or mechanical switches, PNP
Sensor supply US: max. 200 mA from AS-Interface (short-circuit and overload protected)
Fieldbus: A-coded
I/O ports: M12, 4-pole
Bus voltage (AS-Interface): 26.5 - 31.6 V DC
ASI-Power 24: yes
Total current: max. 250 mA
Addressing: via master or M12 connection and programming device
Address range: 1 - 62 (2 x 1 - 31 A or B)
Profile (IO/ID/ID2 code): 2 x S-0.A.2
Address presetting: Slave 1: address 31 A; Slave 2: address 31 B
Protection: IP68
Mounting method: screw fixing
Temperature range: -20 - 60 degrees Celcius (storage temperature -20 - 70 degrees Celcius)
Dimensions H x W x D: 126x30x34.5 mm
Communication status: via LED
Diagnostic via LED: per module
Monitoring - no voltage: yes
The I/O modules of the Murrelektronik MASI68 series, with bus connections and M12 standard cables, are designed for applications in exposed areas that require sealed components. They offer a complete solution with IP68/69K protection. Accessories and special round cables complete the MASI68 range offering you a total installation concept for decentralized installations. Pluggable round cables make installation and service much easier.
Advantages:
Small and compact with high signal density
Sealed to meet industrial requirements
Easy to install with integrated bus distributor
Additional Info
Brand | Murrelektronik |
---|---|
Component Type | Fieldbus Module |
Inputs | 8 |
Material | Plastic |
Murr Product Series | Murrelektronik MASI |
Output Type | PNP |