Image may not be representative of actual product.
Series: MSI-MD-FB
Restart delay time: 100 ms
Supply voltage: 24 V, DC, -20 - 20 %, Compensation necessary at 20 ms voltage dip, min. 250 mA ( external loads)
Number of digital switching inputs: 8
Switching voltage high, min: 27 V
Switching voltage low, max: 2.5 V
Switching voltage, typ: 24 V
Voltage type: DC
Number of safety-related switching inputs: 2
Voltage type: DC
Switching voltage high, min: 27 V
Switching voltage low, max.: 18 V
Switching voltage, typ: 24 V
Number of safety-related switching outputs (OSSDs): 2
Switching voltage high, min: 18 V
Switching voltage low, max: 2.5 V
Switching voltage, typ: 24 V
Voltage type: DC
Number of digital switching outputs: 3
Switching element: Transistor, PNP
Voltage type: DC
Switching voltage, typ: 24 V
Number of connections: 8
Type of connections: M12 connector, USB 2.0 Micro-B
Type of display: LED
Number of LEDs: 14
Degree of protection: IP 67
Certification: TUV Sud
Functions: Sequence controlled 2-sensor muting, Sequence controlled 4-sensor muting, Timing controlled 2-sensor muting, Muting-timeout extension, Muting enable function
Restart: Automatic, Manual
If low safety distances are necessary, the MSI-MD-FB muting controller together with the MLC safety light curtains offer a flexible muting solution. It is installed close to the protective device and combines all the necessary connections for sensors, muting indicators and reset buttons. 3 muting operating modes and other detailed functions ensure optimal adaptation to the application. The muting controller works in combination with both MLC safety light curtains and MLD multiple light beam safety devices.
Advantages:
Full muting functions in combination with the standard variants of the MLC/MLD series
3 muting operating modes: 2 timing controlled sensors, 2 and 4 sequence controlled sensors
Degree of protection IP 67 and durable laser inscription allows for use under harsh ambient conditions
Simple configuration via DIP switch, no PC required
Only a cable to the switch cabinet with a maximum length of 50 m is necessary
Additional Info
Application Function | External Control of Muting Processes |
---|---|
Brand | Leuze |
Component Type | Programmable Safety Control |
Leuze Product Series | Leuze MSI-MD-FB Safety Relay Evaluation Unit |